Tested according to BS1363 plug standard 1363 plug, taking the assembled British plug as an example. In the case of load, the temperature of copper feet does not exceed 37°C of room temperature (the temperature after 4 hours of testing), that is, the temperature rise is 37°C, and the line position of live wire and neutral wire does not exceed 52°C of room temperature. Within the temperature range, the product can be qualified, otherwise it is unqualified.
Take 13A British plug fuse as an example and test according to BS1362 standard. The rated value of the fuse tube carries 1.9 times the current and must be blown within half an hour; the rated value of the fuse tube carries 1.6 times the current and cannot be blown within half an hour.
Specifications
Rated voltage: 230V
Rated current: 3A, 5A, 10A, 13A
Color: conventional black, white, and transparent, pink, green, gray and other colors, color matching.
Fuse: Comply with BS1362 standard, ASTA certified.
Scope of application: It is very suitable for the use of wire rods for export electrical products.
Applicable areas: UK, Hong Kong, Singapore, Malaysia, Middle East countries, India, Pakistan, Vietnam, Bahrain, Bhutan, Brunei, Indonesia, Botswana, Cyprus, Ghana, Kenya, Maldives, Qatar, Zimbabwe, Yemen, Tanzania, etc. .